VRV / VRF air conditioning.

A single refrigerant network to cool and heat a whole building, with the temperature set room by room.

Offices, hotels, public buildings: we design, install, commission and maintain variable refrigerant flow systems, with or without heat recovery, day to day in the Alpes-Maritimes, the Var and Monaco. Based in Nice, we also work on large projects across France.

Illustration: VRV units installed on a flat roof, refrigerant pipework on supports, the city and the sea beyond
VRV / VRF
Design · Install · Follow-up
  1. 4 to 70 kWServicing at least every two years
  2. > 70 kWInspection at least every five years
  3. 5 t CO2eLeak checks: threshold for HFCs

How a VRV / VRF system works

A VRV building, from the roof to the offices

  1. Outdoor unitsThe outdoor units vary the refrigerant flow to match the building's actual needs, instead of running flat out.
  2. Refrigerant networkA single refrigerant network, with its branches, feeds the cassettes, ducted units and wall units on every floor.
  3. Branch boxesIn the heat recovery version, they share out the refrigerant between the units: each one receives heating or cooling, as it needs. The heat taken from a sunny room then warms a room that has stayed cool.
  4. Indoor unitsCeiling cassettes, a ducted unit hidden in the false ceiling, wall units high on the wall: each room gets the unit that suits it.
  5. ControlsEach office or room keeps its own set point, and a central controller runs the whole system.
  • Liquid refrigerant
  • Refrigerant gas
  • Cold air supply
  • Control bus

The buildings we equip

Offices

Open-plan or partitioned floors: each zone sets its own temperature without upsetting the others.

Hotels

Each room has its own controls, and output adapts to the number of occupied rooms.

Restaurants

Ceiling cassettes in the dining room, separate control for the service areas.

Public buildings

Administrative premises and buildings open to the public: a centralised installation that is simple to run and maintain.

In offices, fresh air can come from an air handling unit, and a BMS can supervise the VRV along with the building's other equipment.

A server room is not cooled like an office: see our data centers and IT rooms page.

From design to follow-up.

  1. The design study

    The building, its zones and the space on the roof or in the plant room: we size the outdoor units and the network.

  2. Installation and commissioning

    Outdoor units, refrigerant network, indoor units and controls, installed then commissioned.

  3. Follow-up

    Once the installation is running, we look after it under an HVAC maintenance contract.

To study your project

These details let us size the installation and prepare an accurate quote.

Prepare my request ↗
  • The type of building and its floor area
  • The number of rooms or zones to treat
  • The existing installation, if there is one: brand, age, refrigerant
  • The space available on the roof or in a plant room
  • The preferred schedule for the works

Offices on VRV, in 3D.

In the 3D diagram of our business section, two pipes, liquid and gas, link the office cassettes to the VRV units on the roof.

Your questions about VRV / VRF

What is the difference between VRV and VRF?

None in principle. VRV is one manufacturer's trademark, VRF the general term for "variable refrigerant flow". Both describe the same type of installation.

Should I choose heat recovery?

It is useful when some rooms need cooling while others need heating, for example facades with different exposures or a server room. We check this during the design study.

Can you take over an existing installation?

We start with a survey of the outdoor units, the network, the indoor units and the refrigerant. Depending on the installation's age and condition, we propose a refurbishment or a replacement.

What maintenance does a VRV / VRF system need?

From 4 to 70 kW, servicing every two years is mandatory in France (decree no. 2020-912 of 28 July 2020); above 70 kW, an inspection at least every five years, or every ten years under an ISO 50001-certified energy management system. Leak checks are mandatory when the equipment contains at least 5 tonnes CO2 equivalent of the fluorinated gases in Annex I, including HFCs such as R32, or at least 1 kg of those in Section 1 of Annex II, the unsaturated hydro(chloro)fluorocarbons such as HFOs. Hermetically sealed equipment labelled as such is exempt below 10 tonnes CO2 equivalent, or below 2 kg for Annex II gases (EU Regulation 2024/573, article 5). We include it in a maintenance contract.

A project
or a breakdown?

A few details are enough and we will call you back; the online configurator (optional) lets you detail your project.

By phone Call us Monday to Saturday, 8 am to 6 pm By email contact@athclimatique.com

Your premises,
our advice.

Describe your business and your equipment: we will offer a visit and a proposal suited to your sector and your size.

Direct line Call us Monday to Saturday, 8 am to 6 pm By email contact@athclimatique.com

The form did not load. Email us or call us: