Chillers and chilled water production.

Chillers, hydronic networks and pumps.

Preventive maintenance, repairs, replacement and optimisation of your chillers and their chilled water networks, day to day in the Alpes-Maritimes, the Var and Monaco. Based in Nice, we also work on large projects across France.

Illustration: chillers on the roof of a large building, insulated chilled water pipework and technicians on the walkway
  1. 5 t CO2eLeak checks: threshold for HFCs
  2. 1 kgLeak checks: threshold for HFOs
  3. 10 t CO2eThreshold for hermetically sealed, labelled equipment

From maintenance to replacement.

  1. Preventive maintenance

    Your chillers and chilled water networks maintained under our HVAC maintenance contracts.

  2. Repairs

    A breakdown, an alarm, a chiller that has stopped: call us on +33 9 77 51 62 75 or describe the problem online.

  3. Replacement

    Replacing a chiller or a pump.

  4. Optimisation

    Monitoring of the installation by the BMS: temperatures, pressures, alarms and energy use, to spot drifts.

Chilled water, from the roof to the rooms.

A chilled water plant, in cross-section

  1. ChillerOn the roof, it produces the building's chilled water: its refrigerant circuit takes heat from the water and rejects it outside.
  2. CompressorsThey draw in the refrigerant gas and compress it.
  3. Condenser and fansThey reject the heat taken from the water outside; the refrigerant turns back into a liquid.
  4. EvaporatorThe refrigerant evaporates there, taking heat from the network's water: the water leaves chilled.
  5. PumpIt circulates chilled water through the whole network, from the chiller to the building's circuits and back.
  6. Headers and valvesSupply and return are shared out between the building's circuits; a valve on each supply and each return lets a circuit be isolated.
  7. Air handling unitAir passes through the filter, then the cooling coil, where the chilled water flows; the fan blows it, cooled, to the rooms.
  8. Terminal unitsIn the rooms, they cool each room's air with the chilled water.
  9. Controls and BMSSensors read temperatures and pressures; the BMS also tracks alarms and energy use, to spot drifts.
  • Chilled water · supply
  • Chilled water · return
  • Rejected heat
  • Cold air supply
  • Readings and alarms

In your buildings.

Chillers and chilled water production are part of what we maintain for industry and laboratories and for infrastructure and transport, along with air handling units and the BMS.

Leak checks are mandatory when the equipment contains at least 5 tonnes CO2 equivalent of the fluorinated gases in Annex I, including HFCs such as R32, or at least 1 kg of those in Section 1 of Annex II, the unsaturated hydro(chloro)fluorocarbons such as HFOs. Hermetically sealed equipment labelled as such is exempt below 10 tonnes CO2 equivalent, or below 2 kg for Annex II gases (EU Regulation 2024/573, article 5). The technician works this out from the charge shown on the rating plate.

For cold rooms and the units that serve them, see our cold rooms page.

Chilled water also cools IT rooms: see our data center and server room cooling page.

Chillers, in 3D.

The rooftop chillers, and the air handling unit with its chilled water coil, in the 3D diagram of our business section.

Your questions about chillers

Discuss your project →
Do you maintain chillers?

Yes, along with their chilled water networks, under our HVAC maintenance contracts.

A project
or a breakdown?

A few details are enough and we will call you back; the online configurator (optional) lets you detail your project.

By phone Call us Monday to Saturday, 8 am to 6 pm By email contact@athclimatique.com

Your premises,
our advice.

Describe your business and your equipment: we will offer a visit and a proposal suited to your sector and your size.

Direct line Call us Monday to Saturday, 8 am to 6 pm By email contact@athclimatique.com

The form did not load. Email us or call us: