Server room and data center cooling.

Precision cooling, from the rack to the chiller.

A server room gives off heat day and night, all year round. For your IT rooms and data centers, including a local edge data center, we bring our trades together: chilled water production, air handling, monitoring and maintenance, day to day in the Alpes-Maritimes, the Var and Monaco. Based in Nice, we also work on large projects across France.

Illustration: cutaway of a server room, rack rows with contained cold aisles under a glass roof, in-row cooling units, hot aisles and cable trays
  1. 18 to 27 °CRecommended air temperature at the server inlet
  2. N+1One more cooling unit than the load requires
  3. PUETotal site energy divided by IT energy

Source: ASHRAE, “Thermal Guidelines for Data Processing Environments”, recommended range for most IT equipment; the server manufacturer's setting prevails if it is stricter.

Why a server room is not cooled like an office.

Heat from the racks

Servers turn almost all the electricity they use into heat, day and night, summer and winter. Comfort air conditioning, designed for offices used during the day, is not built for this continuous duty.

Continuity of service

If cooling stops, the room heats up and the servers end up shutting down to protect themselves. Hence a standby unit, a temperature alarm and regular maintenance.

Energy

Cooling weighs heavily in a room's energy use. Contained aisles, the right set points and free cooling when the outdoor air is cool enough can reduce it; the PUE lets you track it.

Humidity and air

Air that is too dry encourages static electricity, air that is too humid causes condensation. Precision cooling controls temperature and humidity, and filters the room's air.

A few racks in a small room, or a whole room: we look at the room, its racks and its equipment with you before proposing a solution.

From the rack to the roof: cooling an IT room.

An IT room, in cross-section

  1. Racks in rowsServers draw in cool air at the front and expel hot air at the back: racks face each other in pairs, hence a cold aisle and a hot aisle.
  2. ContainmentDoors and a roof enclose the cold aisle, or the hot aisle: the cold air goes to the servers instead of mixing with the hot air.
  3. Precision coolingUnits at the edge of the room, or within the rows, blow cold air, take back the hot air and also control humidity.
  4. Chilled water loopChilled water carries cooling to the room's units and returns, warmed, to where it is produced.
  5. Chilled water productionThe chiller, on the roof or in a plant room, produces the chilled water and rejects the servers' heat outdoors. A small room can also be cooled by direct expansion, with its outdoor units.
  6. Free coolingWhen the outdoor air is cool enough, it cools the water directly: the compressors stop or run less.
  7. N+1 redundancyOne more unit than the load requires: one can stop, for a breakdown or maintenance, without cutting off the room's cooling.
  8. Supervision and alarmsTemperature and humidity sensors, alarms and energy use report to the BMS, along with the building's other equipment.
  • Cold air supply
  • Hot air return and discharge
  • Chilled water · supply
  • Chilled water · return
  • Readings and alarms
Illustration: in-row cooling, cold air blown into the contained aisle towards the rack fronts, hot air drawn back from the rear
In-row cooling units
Illustration: two air-cooled chillers on the plant room roof, chilled water pipework on supports
Chilled water production on the roof

What we do for your IT rooms.

  1. Visit and quote

    We come to see the room, its racks and its equipment, then give you a quote. Free quote and technical visit.

  2. Chilled water and air handling

    We maintain, repair and replace chillers and their chilled water networks, and we install, maintain and adjust air handling units.

  3. Supervision and alarms

    With a BMS, the room's temperatures, alarms and energy use are monitored with the rest of the building; we maintain it under our contracts.

  4. Maintenance and repairs

    Scheduled visits and a report after each one under our HVAC maintenance contracts. A breakdown: call us on +33 9 77 51 62 75 or describe the problem online.

The offices next to the room are air-conditioned separately, for example with VRV / VRF air conditioning.

Where we work: around Sophia Antipolis (Antibes, Valbonne, Biot, Mougins), in Nice, in Monaco and in the Var, Toulon included.

Your questions about server rooms

Discuss your project →
What temperature should a server room be?

According to ASHRAE guidelines, the air entering the servers should stay between 18 and 27 °C; the server manufacturer's setting prevails if it is stricter.

What counts is the air at the rack inlet, not the average room temperature.

Is office air conditioning enough for a server room?

Comfort air conditioning is designed for offices used during the day. A server room gives off heat day and night, all year round: its cooling runs continuously, also controls humidity, is watched by an alarm and is planned with a standby unit.

We look at the room, its racks and its equipment with you before proposing a solution.

What does N+1 redundancy mean?

One more cooling unit than the load requires: one can stop, for a breakdown or maintenance, without cutting off the room's cooling.

What is cold aisle containment?

Racks face each other in pairs, hence a cold aisle and a hot aisle. Doors and a roof enclose the cold aisle, or the hot aisle: the cold air goes to the servers instead of mixing with the hot air.

What is free cooling?

When the outdoor air is cool enough, it cools the water directly: the compressors stop or run less.

How much of the year it can be used depends on the climate and the room temperatures: it is assessed site by site.

Do you offer a maintenance contract for a server room?

Our HVAC maintenance contracts cover chillers, air handling units and the BMS, with scheduled visits and a report after each one.

With the Premium plan, out-of-hours on-call cover is available as an option, on quote.

What should I do if the server room cooling breaks down?

Call us on +33 9 77 51 62 75, Monday to Saturday, 8 am to 6 pm, or describe the problem online.

A temperature alarm can be linked to a BMS, to give warning when the room heats up.

Where do you work?

Day to day in Nice, the Alpes-Maritimes, including Sophia Antipolis, the Var and Monaco, and also on large projects across France.

We work around Sophia Antipolis (Antibes, Valbonne, Biot, Mougins), in Nice, in Monaco and in the Var, Toulon included.

A project
or a breakdown?

A few details are enough and we will call you back; the online configurator (optional) lets you detail your project.

By phone Call us Monday to Saturday, 8 am to 6 pm By email contact@athclimatique.com

Your premises,
our advice.

Describe your business and your equipment: we will offer a visit and a proposal suited to your sector and your size.

Direct line Call us Monday to Saturday, 8 am to 6 pm By email contact@athclimatique.com

The form did not load. Email us or call us: